Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
1.
Placenta ; 151: 19-25, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38657321

RESUMO

INTRODUCTION: Placental insufficiency may lead to preeclampsia and fetal growth restriction. There is no cure for placental insufficiency, emphasizing the need for monitoring fetal and placenta health. Current monitoring methods are limited, underscoring the necessity for imaging techniques to evaluate fetal-placental perfusion and oxygenation. This study aims to use MRI to evaluate placental oxygenation and perfusion in the reduced uterine perfusion pressure (RUPP) model of placental insufficiency. METHODS: Pregnant rats were randomized to RUPP (n = 11) or sham surgery (n = 8) on gestational day 14. On gestational day 19, rats imaged using a 7T MRI scanner to assess oxygenation and perfusion using T2* mapping and 3D-DCE MRI sequences, respectively. The effect of the RUPP on the feto-placental units were analyzed from the MRI images. RESULTS: RUPP surgery led to reduced oxygenation in the labyrinth (24.7 ± 1.8 ms vs. 28.0 ± 2.1 ms, P = 0.002) and junctional zone (7.0 ± 0.9 ms vs. 8.1 ± 1.1 ms, P = 0.04) of the placenta, as indicated by decreased T2* values. However, here were no significant differences in fetal organ oxygenation or placental perfusion between RUPP and sham animals. DISCUSSION: The reduced placental oxygenation without a corresponding decrease in perfusion suggests an adaptive response to placental ischemia. While acute reduction in placental perfusion may cause placental hypoxia, persistence of this condition could indicate chronic placental insufficiency after ischemic reperfusion injury. Thus, placental oxygenation may be a more reliable biomarker for assessing fetal condition than perfusion in hypertensive disorders of pregnancies including preeclampsia and FGR.

2.
Phys Med Biol ; 69(8)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38471172

RESUMO

Objective.To improve hyperthermia in clinical practice, pre-clinical hyperthermia research is essential to investigate hyperthermia effects and assess novel treatment strategies. Translating pre-clinical hyperthermia findings into clinically viable protocols requires laboratory animal treatment techniques similar to clinical hyperthermia techniques. The ALBA micro8 electromagnetic heating system (Med-logix SRL, Rome, Italy) has recently been developed to provide the targeted locoregional tumour heating currently lacking for pre-clinical research. This study evaluates the heat focusing properties of this device and its ability to induce robust locoregional tumour heating under realistic physiological conditions using simulations.Approach.Simulations were performed using the Plan2Heat treatment planning package (Amsterdam UMC, the Netherlands). First, the specific absorption rate (SAR) focus was characterised using a homogeneous phantom. Hereafter, a digital mouse model was used for the characterisation of heating robustness in a mouse. Device settings were optimised for treatment of a pancreas tumour and tested for varying circumstances. The impact of uncertainties in tissue property and perfusion values was evaluated using polynomial chaos expansion. Treatment quality and robustness were evaluated based on SAR and temperature distributions.Main results.The SAR distributions within the phantom are well-focused and can be adjusted to target any specific location. The focus size (full-width half-maximum) is a spheroid with diameters 9 mm (radially) and 20 mm (axially). The mouse model simulations show strong robustness against respiratory motion and intestine and stomach filling (∆T90≤0.14°C).Mouse positioning errors in the cranial-caudal direction lead to∆T90≤0.23°C. Uncertainties in tissue property and perfusion values were found to impact the treatment plan up to 0.56 °C (SD), with a variation onT90of 0.32 °C (1 SD).Significance.Our work shows that the pre-clinical phased-array system can provide adequate and robust locoregional heating of deep-seated target regions in mice. Using our software, robust treatment plans can be generated for pre-clinical hyperthermia research.


Assuntos
Hipertermia Induzida , Neoplasias , Animais , Camundongos , Calefação , Neoplasias/terapia , Hipertermia Induzida/métodos , Temperatura Alta , Software
3.
Eur Radiol Exp ; 8(1): 38, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38499843

RESUMO

BACKGROUND: Intravoxel incoherent motion (IVIM)-corrected diffusion tensor imaging (DTI) potentially enhances return-to-play (RTP) prediction after hamstring injuries. However, the long scan times hamper clinical implementation. We assessed accelerated IVIM-corrected DTI approaches in acute hamstring injuries and explore the sensitivity of the perfusion fraction (f) to acute muscle damage. METHODS: Athletes with acute hamstring injury received DTI scans of both thighs < 7 days after injury and at RTP. For a subset, DTI scans were repeated with multiband (MB) acceleration. Data from standard and MB-accelerated scans were fitted with standard and accelerated IVIM-corrected DTI approach using high b-values only. Segmentations of the injury and contralateral healthy muscles were contoured. The fitting methods as well as the standard and MB-accelerated scan were compared using linear regression analysis. For sensitivity to injury, Δ(injured minus healthy) DTI parameters between the methods and the differences between injured and healthy muscles were compared (Wilcoxon signed-rank test). RESULTS: The baseline dataset consisted of 109 athletes (16 with MB acceleration); 64 of them received an RTP scan (8 with MB acceleration). Linear regression of the standard and high-b DTI fitting showed excellent agreement. With both fitting methods, standard and MB-accelerated scans were comparable. Δ(injured minus healthy) was similar between standard and accelerated methods. For all methods, all IVIM-DTI parameters except f were significantly different between injured and healthy muscles. CONCLUSIONS: High-b DTI fitting with MB acceleration reduced the scan time from 11:08 to 3:40 min:s while maintaining sensitivity to hamstring injuries; f was not different between healthy and injured muscles. RELEVANCE STATEMENT: The accelerated IVIM-corrected DTI protocol, using fewer b-values and MB acceleration, reduced the scan time to under 4 min without affecting the sensitivity of the quantitative outcome parameters to hamstring injuries. This allows for routine clinical monitoring of hamstring injuries, which could directly benefit injury treatment and monitoring. KEY POINTS: • Combining high-b DTI-fitting and multiband-acceleration dramatically reduced by two thirds the scan time. • The accelerated IVIM-corrected DTI approaches maintained the sensitivity to hamstring injuries. • The IVIM-derived perfusion fraction was not sensitive to hamstring injuries.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física)
4.
BMJ Open Sport Exerc Med ; 10(1): e001778, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38347856

RESUMO

Objectives: To investigate the association between leisure time physical activity (LTPA) and MRI-based diastolic function and the mediating role of metabolic health. Methods: This cross-sectional analysis comprised 901 participants (46% women, mean age (SD): 56 (6) years (The Netherlands, 2008-2012)). LTPA was assessed via questionnaire, quantified in metabolic equivalent of tasks (METs)-minutes per week and participants underwent abdominal and cardiovascular MRI. Confirmatory factor analysis was used to construct the metabolic load factor. Piecewise structural equation model with adjustments for confounders was used to determine associations between LTPA and diastolic function and the mediating effect of metabolic load. Results: Significant differences in mitral early/late peak filling rate (E/A) ratio per SD of LTPA (men=1999, women=1870 MET-min/week) of 0.18, (95% CI= 0.03 to 0.33, p=0.021) were observed in men, but not in women: -0.01 (-0.01 to 0.34, p=0.058). Difference in deceleration time of mitral early filling (E-DT) was 0.13 (0.01 to 0.24, p=0.030) in men and 0.17 (0.05 to 0.28, p=0.005) in women. Metabolic load, including MRI-based visceral and subcutaneous adipose tissue, fasting glucose, high-density lipoprotein cholesterol and triglycerides, mediated these associations as follows: E/A-ratio of 0.030 (0.000 to 0.067, 19% mediated, p=0.047) in men but not in women: 0.058 (0.027 to 0.089, p<0.001) and E-DT not in men 0.004 (-0.012 to 0.021, p=0.602) but did in women 0.044 (0.013 to 0.057, 27% mediated, p=0.006). Conclusions: A larger amount of LTPA was associated with improved diastolic function where confirmatory factor analysis-based metabolic load partly mediated this effect. Future studies should assess whether improving indicators of metabolic load alongside LTPA will benefit healthy diastolic function even more.

5.
Tissue Eng Part A ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38420632

RESUMO

An essential aspect of cardiovascular in situ tissue engineering (TE) is to ensure balance between scaffold degradation and neo-tissue formation. We evaluated the rate of degradation and neo-tissue formation of three electrospun supramolecular bisurea-based biodegradable scaffolds that differ in their soft-block backbone compositions only. Scaffolds were implanted as interposition grafts in the abdominal aorta in rats, and evaluated at different time points (t = 1, 6, 12, 24, and 40 weeks) on function, tissue formation, strength, and scaffold degradation. The fully carbonate-based biomaterial showed minor degradation after 40 weeks in vivo, whereas the other two ester-containing biomaterials showed (near) complete degradation within 6-12 weeks. Local dilatation was only observed in these faster degrading scaffolds. All materials showed to some extent mineralization, at early as well as late time points. Histological evaluation showed equal and non-native-like neo-tissue formation after total degradation. The fully carbonate-based scaffolds lagged in neo-tissue formation, presumably as its degradation was (far from) complete at 40 weeks. A significant difference in vessel wall contrast enhancement was observed by magnetic resonance imaging between grafts with total compared with minimal-degraded scaffolds.

7.
NMR Biomed ; 37(3): e5064, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38062865

RESUMO

Static quantitative magnetic resonance imaging (MRI) provides readouts of structural changes in diseased muscle, but current approaches lack the ability to fully explain the loss of contractile function. Muscle contractile function can be assessed using various techniques including phase-contrast MRI (PC-MRI), where strain rates are quantified. However, current two-dimensional implementations are limited in capturing the complex motion of contracting muscle in the context of its three-dimensional (3D) fiber architecture. The MR acquisitions (chemical shift-encoded water-fat separation scan, spin echo-echoplanar imaging with diffusion weighting, and two time-resolved 3D PC-MRI) wereperformed at 3 T. PC-MRI acquisitions and performed with and without load at 7.5% of the maximum voluntary dorsiflexion contraction force. Acquisitions (3 T, chemical shift-encoded water-fat separation scan, spin echo-echo planar imaging with diffusion weighting, and two time-resolved 3D PC-MRI) were performed with and without load at 7.5% of the maximum voluntary dorsiflexion contraction force. Strain rates and diffusion tensors were calculated and combined to obtain strain rates along and perpendicular to the muscle fibers in seven lower leg muscles during the dynamic dorsi-/plantarflexion movement cycle. To evaluate strain rates along the proximodistal muscle axis, muscles were divided into five equal segments. t-tests were used to test if cyclic strain rate patterns (amplitude > 0) were present along and perpendicular to the muscle fibers. The effects of proximal-distal location and load were evaluated using repeated measures ANOVAs. Cyclic temporal strain rate patterns along and perpendicular to the fiber were found in all muscles involved in dorsi-/plantarflexion movement (p < 0.0017). Strain rates along and perpendicular to the fiber were heterogeneously distributed over the length of most muscles (p < 0.003). Additional loading reduced strain rates of the extensor digitorum longus and gastrocnemius lateralis muscle (p < 0.001). In conclusion, the lower leg muscles involved in cyclic dorsi-/plantarflexion exercise showed cyclic fiber strain rate patterns with amplitudes that varied between muscles and between the proximodistal segments within the majority of muscles.


Assuntos
Tornozelo , Perna (Membro) , Humanos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Imageamento por Ressonância Magnética/métodos , Fibras Musculares Esqueléticas , Água
8.
Front Cardiovasc Med ; 10: 1285206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38089763

RESUMO

Introduction: Current practice to obtain left ventricular (LV) native and post-contrast T1 and T2 comprises single-slice readouts with multiple breath-holds (BHs). We propose a multi-slice parallel-imaging approach with a 72-channel receive-array to reduce BHs and demonstrate this in healthy subjects and hypertrophic cardiomyopathy (HCM) patients. Methods: A T1/T2 phantom was scanned at 3 T using a 16-channel and a novel 72-channel coil to assess the impact of different coils and acceleration factors on relaxation times. 16-18 healthy participants (8 female, age 28.4 ± 5.1 years) and 3 HCM patients (3 male, age 55.3 ± 4.2 years) underwent cardiac-MRI with the 72-channel coil, using a Modified Look-Locker scan with a shared inversion pulse across 3 slices and a Gradient-Spin-Echo scan. Acceleration was done by sensitivity encoding (SENSE) with accelerations 2, 4, and 6. LV T1 and T2 values were analyzed globally, per slice, and in 16 segments, with SENSE = 2 as the reference. Results: The phantom scans revealed no bias between coils and acceleration factors for T1 or T2, except for T2 with SENSE = 2, which resulted in a bias of 8.0 ± 6.7 ms (p < 0.001) between coils. SENSE = 4 and 6 enabled T1 mapping of three slices in a single BH, and T2 mapping of three slices within two BHs. In healthy subjects, T1 and T2 values varied. We found an average overestimation of T1 in 3 slices of 25 ± 87 ms for SENSE = 4 and 30 ± 103 ms using SENSE = 6, as compared to SENSE = 2. Acceleration resulted in decreased signal-to-noise; however, visually insignificant and without increased incidence of SENSE-artifacts. T2 was overestimated by 2.1 ± 5.0 ms for SENSE = 4 and 6.4 ± 9.7 ms using SENSE = 6, as compared to SENSE = 2. Native and post-contrast T1 measurements with SENSE = 4 and ECV quantification in HCM patients was successful. Conclusion: The 72-channel receiver-array coil with SENSE = 4 and 6, enabled LV-tissue characterization in three slices. Pre- and post-contrast T1 maps were obtained in a single BH, while T2 required two BHs.

9.
AJNR Am J Neuroradiol ; 44(10): 1157-1164, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37770205

RESUMO

BACKGROUND AND PURPOSE: White matter lesions are commonly found in patients with Fabry disease. Existing studies have shown elevated diffusivity in healthy-appearing brain regions that are commonly associated with white matter lesions, suggesting that DWI could help detect white matter lesions at an earlier stage This study explores whether diffusivity changes precede white matter lesion formation in a cohort of patients with Fabry disease undergoing yearly MR imaging examinations during a 5-year period. MATERIALS AND METHODS: T1-weighted anatomic, FLAIR, and DWI scans of 48 patients with Fabry disease (23 women; median age, 44 years; range, 15-69 years) were retrospectively included. White matter lesions and tissue probability maps were segmented and, together with ADC maps, were transformed into standard space. ADC values were determined within lesions before and after detection on FLAIR images and compared with normal-appearing white matter ADC. By means of linear mixed-effects modeling, changes in ADC and ΔADC (relative to normal-appearing white matter) across time were investigated. RESULTS: ADC was significantly higher within white matter lesions compared with normal-appearing white matter (P < .01), even before detection on FLAIR images. ADC and ΔADC were significantly affected by sex, showing higher values in men (60.1 [95% CI, 23.8-96.3] ×10-6mm2/s and 35.1 [95% CI, 6.0-64.2] ×10-6mm2/s), respectively. ΔADC increased faster in men compared with women (0.99 [95% CI, 0.27-1.71] ×10-6mm2/s/month). ΔADC increased with time even when only considering data from before detection (0.57 [95% CI, 0.01-1.14] ×10-6mm2/s/month). CONCLUSIONS: Our results indicate that in Fabry disease, changes in diffusion precede the formation of white matter lesions and that microstructural changes progress faster in men compared with women. These findings suggest that DWI may be of predictive value for white matter lesion formation in Fabry disease.


Assuntos
Doença de Fabry , Doenças Vasculares , Masculino , Humanos , Feminino , Adulto , Estudos Retrospectivos , Doença de Fabry/diagnóstico por imagem , Doença de Fabry/patologia , Seguimentos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos
10.
NMR Biomed ; : e5029, 2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37658736

RESUMO

Cerebrospinal fluid (CSF) has historically been considered to function as a sink for brain-derived waste disposal. Recent work suggested that CSF interacts even more intensely with brain tissue than previously recognized, through perivascular spaces that penetrate the brain. Cardiac pulsations, vasomotion, and respiration have been suggested to drive CSF flow in these perivascular spaces, thereby enhancing waste clearance. However, the intrinsic role of CSF production in relation to its distribution volume (turnover) is not an explicit component of recent concepts on brain clearance. Here, we review the work on CSF turnover and volume, focusing on preclinical evidence. Herein, we highlight the use of MRI in establishing CSF-related parameters. We describe the impact of sleep, effect of anesthesia, aging, and hypertension on CSF turnover, and how this relates to brain clearance. Evaluation of the available evidence suggests that CSF turnover is a major determinant in brain clearance. In addition, we propose that several putative drivers of brain clearance, but also conditions associated with impaired clearance, such as aging, may actually relate to altered CSF turnover.

11.
Cells ; 12(16)2023 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-37626890

RESUMO

Placental hypoxia poses significant risks to both the developing fetus and the mother during pregnancy, underscoring the importance of early detection and monitoring. Effectively identifying placental hypoxia and evaluating the deterioration in placental function requires reliable biomarkers. Molecular biomarkers in placental tissue can only be determined post-delivery and while maternal blood biomarkers can be measured over time, they can merely serve as proxies for placental function. Therefore, there is an increasing demand for non-invasive imaging techniques capable of directly assessing the placental condition over time. Recent advancements in imaging technologies, including photoacoustic and magnetic resonance imaging, offer promising tools for detecting and monitoring placental hypoxia. Integrating molecular and imaging biomarkers may revolutionize the detection and monitoring of placental hypoxia, improving pregnancy outcomes and reducing long-term health complications. This review describes current research on molecular and imaging biomarkers of placental hypoxia both in human and animal studies and aims to explore the benefits of an integrated approach throughout gestation.


Assuntos
Insuficiência Placentária , Gravidez , Animais , Humanos , Feminino , Insuficiência Placentária/diagnóstico por imagem , Placenta/diagnóstico por imagem , Síndrome , Biomarcadores , Hipóxia
12.
J Am Coll Cardiol ; 82(8): 704-717, 2023 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-37587582

RESUMO

BACKGROUND: Precapillary pulmonary hypertension (precPH) patients have altered right atrial (RA) function and right ventricular (RV) diastolic stiffness. OBJECTIVES: This study aimed to investigate RA function using pressure-volume (PV) loops, isolated cardiomyocyte, and histological analyses. METHODS: RA PV loops were constructed in control subjects (n = 9) and precPH patients (n = 27) using magnetic resonance and catheterization data. RA stiffness (pressure rise during atrial filling) and right atrioventricular coupling index (RA minimal volume / RV end-diastolic volume) were compared in a larger cohort of patients with moderate (n = 39) or severe (n = 41) RV diastolic stiffness. Cardiomyocytes were isolated from RA tissue collected from control subjects (n = 6) and precPH patients (n = 9) undergoing surgery. Autopsy material was collected from control subjects (n = 6) and precPH patients (n = 4) to study RA hypertrophy, capillarization, and fibrosis. RESULTS: RA PV loops showed 3 RA cardiac phases (reservoir, passive emptying, and contraction) with dilatation and elevated pressure in precPH. PrecPH patients with severe RV diastolic stiffness had increased RA stiffness and worse right atrioventricular coupling index. Cardiomyocyte cross-sectional area was increased 2- to 3-fold in precPH, but active tension generated by the sarcomeres was unaltered. There was no increase in passive tension of the cardiomyocytes, but end-stage precPH showed reduced number of capillaries per mm2 accompanied by interstitial and perivascular fibrosis. CONCLUSIONS: RA PV loops show increased RA stiffness and suggest atrioventricular uncoupling in patients with severe RV diastolic stiffness. Isolated RA cardiomyocytes of precPH patients are hypertrophied, without intrinsic sarcomeric changes. In end-stage precPH, reduced capillary density is accompanied by interstitial and perivascular fibrosis.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Hipertensão Pulmonar , Humanos , Miócitos Cardíacos , Átrios do Coração/diagnóstico por imagem
13.
JACC Basic Transl Sci ; 8(7): 801-816, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37547068

RESUMO

In the past 2 decades, research on atherosclerotic cardiovascular disease has uncovered inflammation to be a key driver of the pathophysiological process. A pressing need therefore exists to quantitatively and longitudinally probe inflammation, in preclinical models and in cardiovascular disease patients, ideally using non-invasive methods and at multiple levels. Here, we developed and employed in vivo multiparametric imaging approaches to investigate the immune response following myocardial infarction. The myocardial infarction models encompassed either transient or permanent left anterior descending coronary artery occlusion in C57BL/6 and Apoe-/-mice. We performed nanotracer-based fluorine magnetic resonance imaging and positron emission tomography (PET) imaging using a CD11b-specific nanobody and a C-C motif chemokine receptor 2-binding probe. We found that immune cell influx in the infarct was more pronounced in the permanent occlusion model. Further, using 18F-fluorothymidine and 18F-fluorodeoxyglucose PET, we detected increased hematopoietic activity after myocardial infarction, with no difference between the models. Finally, we observed persistent systemic inflammation and exacerbated atherosclerosis in Apoe-/- mice, regardless of which infarction model was used. Taken together, we showed the strengths and capabilities of multiparametric imaging in detecting inflammatory activity in cardiovascular disease, which augments the development of clinical readouts.

14.
Eur Radiol Exp ; 7(1): 28, 2023 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-37271766

RESUMO

BACKGROUND: This study aimed to assess the feasibility of postmortem ultra-high-field magnetic resonance imaging (UHF-MRI) to study fetal musculoskeletal anatomy and explore the contribution of variation in iodine and formaldehyde (paraformaldehyde, PFA) treatment of tissue. METHODS: Seven upper extremities from human fetuses with gestational ages of 19 to 24 weeks were included in this experimental study, approved by the Medical Research Ethics Committee. The specimens were treated with various storage (0.2-4% PFA) and staining (Lugol's solution) protocols and the wrist joint was subsequently imaged with 7.0 T UHF-MRI. Soft-tissue contrast was quantified by determining regions of interest within a chondrified carpal bone (CCB) from the proximal row, the triangular fibrocartilage (TFC), and the pronator quadratus muscle (PQM) and calculating the contrast ratios (CRs) between mean signal intensities of CCB to TFC and CCB to PQM. RESULTS: UHF-MRI showed excellent soft-tissue contrast in different musculoskeletal tissues. Increasing storage time in 4% PFA, CRs decreased, resulting in a shift from relatively hyperintense to hypointense identification of the CCB. Storage in 0.2% PFA barely influenced the CRs over time. Lugol's solution caused an increase in CRs and might have even contributed to the inversion of the CRs. CONCLUSIONS: UHF-MRI is a feasible technique to image musculoskeletal structures in fetal upper extremities and most successful after short storage in 4% PFA or prolonged storage in 0.2% PFA. The use of Lugol's solution is not detrimental on soft-tissue MRI contrast and therefore enables effectively combining UHF-MRI with contrast-enhanced micro-computed tomography using a single preparation of the specimen. RELEVANCE STATEMENT: UHF-MRI can be performed after CE-micro-CT to take advantage of both techniques. KEY POINTS: • UHF-MRI is feasible to study human fetal cartilaginous and ligamentous anatomy. • Storage in low PFA concentrations (i.e., 0.2%) improves soft-tissue contrast in UHF-MRI. • Limited preservation time in high concentrations of PFA improves soft-tissue contrast in UHF-MRI. • Prior staining with Lugol's solution does not reduce soft-tissue contrast in UHF-MRI.


Assuntos
Feto , Articulação do Punho , Humanos , Microtomografia por Raio-X/métodos , Feto/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Músculo Esquelético , Imageamento por Ressonância Magnética/métodos
15.
J Magn Reson Imaging ; 58(6): 1903-1914, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37092724

RESUMO

BACKGROUND: Oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) may serve as biomarkers in several diseases. OEF and CMRO2 can be estimated from venous blood oxygenation (Yv ) levels, which in turn can be calculated from venous blood T2 values (T2b ). T2b can be measured using different MRI sequences, including T2-relaxation-under-spin-tagging (TRUST) and T2-prepared-blood-relaxation-imaging-with-inversion-recovery (T2-TRIR). The latter measures both T2b and T1 (T1b ) but was found previously to overestimate T2b compared to TRUST. It remained unclear, however, if this bias is constant across higher and lower oxygen saturations. PURPOSE: To compare TRUST and T2-TRIR across a range of O2 saturations using hypoxic and hypercapnic gas challenges. STUDY TYPE: Prospective. POPULATION: Twelve healthy volunteers (four female, age 36 ± 10 years). FIELD STRENGTH/SEQUENCE: A 3T; turbo-field echo-planar-imaging (TFEPI), echo-planar-imaging (EPI), and fast-field-echo (FFE). ASSESSMENT: TRUST- and T2-TRIR-derived T2b , Yv , OEF, and CMRO2 were compared across different respiratory challenges. T1b from T2-TRIR was used to estimate Hct (HctTRIR ) and compared with venipuncture (HctVP ). STATISTICAL TESTS: Shapiro-Wilk, one-sample and paired-sample t-test, repeated measures ANOVA, Friedman test, Bland-Altman, and correlation analysis. Bonferroni multiple-comparison correction was performed. Significance level was 0.05. RESULTS: A significant bias was observed between TRUST- and T2-TRIR-derived T2b , Yv , and OEF values (-13 ± 11 msec, -5.3% ± 3.5% and 5.9 ± 4.1%, respectively). For Yv and OEF, this bias was constant across the range of measured values. T1b was significantly lower during severe hypoxia and hypercapnia compared to baseline (1712 ± 86 msec and 1634 ± 79 msec compared to 1757 ± 90 msec). While no significant bias was found between HctVP and HctTRIR (0.02% ± 0.06%, P = 0.20), the correlation between these Hct values was significant but weak (r = 0.19). DATA CONCLUSION: Given the constant bias, TRUST- and T2-TRIR-derived venous T2b values can be used interchangeably to estimate Yv , OEF, and CMRO2 across a broad range of oxygen saturations. Hct from T2-TRIR-derived T1-values only weakly correlated with Hct from venipuncture. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Hipercapnia , Oxigênio , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Hipercapnia/diagnóstico por imagem , Hipercapnia/metabolismo , Estudos Prospectivos , Oxigênio/metabolismo , Hipóxia/metabolismo , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Circulação Cerebrovascular , Consumo de Oxigênio
16.
NMR Biomed ; 36(8): e4927, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36932842

RESUMO

Intravoxel incoherent motion (IVIM) imaging and diffusion tensor imaging (DTI) facilitate noninvasive quantification of tissue perfusion and diffusion. Both are promising biomarkers in various diseases and a combined acquisition is therefore desirable. This comes with challenges, including noisy parameter maps and long scan times, especially for the perfusion fraction f and pseudo-diffusion coefficient D*. A model-based reconstruction has the potential to overcome these challenges. As a first step, our goal was to develop a model-based reconstruction framework for IVIM and combined IVIM-DTI parameter estimation. The IVIM and IVIM-DTI models were implemented in the PyQMRI model-based reconstruction framework and validated with simulations and in vivo data. Commonly used voxel-wise nonlinear least-squares fitting was used as the reference. Simulations with the IVIM and IVIM-DTI models were performed with 100 noise realizations to assess accuracy and precision. Diffusion-weighted data were acquired for IVIM reconstruction in the liver (n = 5), as well as for IVIM-DTI in the kidneys (n = 5) and lower-leg muscles (n = 6) of healthy volunteers. The median and interquartile range (IQR) values of the IVIM and IVIM-DTI parameters were compared to assess bias and precision. With model-based reconstruction, the parameter maps exhibited less noise, which was most pronounced in the f and D* maps, both in the simulations and in vivo. The bias values in the simulations were comparable between model-based reconstruction and the reference method. The IQR was lower with model-based reconstruction compared with the reference for all parameters. In conclusion, model-based reconstruction is feasible for IVIM and IVIM-DTI and improves the precision of the parameter estimates, particularly for f and D* maps.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Movimento (Física) , Imagem de Difusão por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Músculo Esquelético
17.
Sci Rep ; 13(1): 3481, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859481

RESUMO

Midlife hypertension is an important risk factor for cognitive impairment and dementia, including Alzheimer's disease. We investigated the effects of long-term treatment with two classes of antihypertensive drugs to determine whether diverging mechanisms of blood pressure lowering impact the brain differently. Spontaneously hypertensive rats (SHR) were either left untreated or treated with a calcium channel blocker (amlodipine) or beta blocker (atenolol) until one year of age. The normotensive Wistar Kyoto rat (WKY) was used as a reference group. Both drugs lowered blood pressure equally, while only atenolol decreased heart rate. Cerebrovascular resistance was increased in SHR, which was prevented by amlodipine but not atenolol. SHR showed a larger carotid artery diameter with impaired pulsatility, which was prevented by atenolol. Cerebral arteries demonstrated inward remodelling, stiffening and endothelial dysfunction in SHR. Both treatments similarly improved these parameters. MRI revealed that SHR have smaller brains with enlarged ventricles. In addition, neurofilament light levels were increased in cerebrospinal fluid of SHR. However, neither treatment affected these parameters. In conclusion, amlodipine and atenolol both lower blood pressure, but elicit a different hemodynamic profile. Both medications improve cerebral artery structure and function, but neither drug prevented indices of brain damage in this model of hypertension.


Assuntos
Hipertensão , Hipotensão , Ratos , Animais , Anti-Hipertensivos , Ratos Endogâmicos SHR , Atenolol , Anlodipino , Ratos Endogâmicos WKY , Artéria Carótida Primitiva
18.
MAGMA ; 36(5): 701-709, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36820958

RESUMO

OBJECTIVE: Quantitative extracellular volume fraction (ECV) mapping with MRI is commonly used to investigate in vivo diffuse myocardial fibrosis. This study aimed to validate ECV measurements against ex vivo histology of myocardial tissue samples from patients with aortic valve stenosis or hypertrophic cardiomyopathy. MATERIALS AND METHODS: Sixteen patients underwent MRI examination at 3 T to acquire native T1 maps and post-contrast T1 maps after gadobutrol administration, from which hematocrit-corrected ECV maps were estimated. Intra-operatively obtained myocardial tissue samples from the same patients were stained with picrosirius red for quantitative histology of myocardial interstitial fibrosis. Correlations between in vivo ECV and ex vivo myocardial collagen content were evaluated with regression analyses. RESULTS: Septal ECV was 30.3% ± 4.6% and correlated strongly (n = 16, r = 0.70; p = 0.003) with myocardial collagen content. Myocardial native T1 values (1206 ± 36 ms) did not correlate with septal ECV (r = 0.41; p = 0.111) or with myocardial collagen content (r = 0.32; p = 0.227). DISCUSSION: We compared myocardial ECV mapping at 3 T against ex vivo histology of myocardial collagen content, adding evidence to the notion that ECV mapping is a surrogate marker for in vivo diffuse myocardial fibrosis.


Assuntos
Estenose da Valva Aórtica , Cardiomiopatias , Cardiomiopatia Hipertrófica , Humanos , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Biópsia , Reprodutibilidade dos Testes , Miocárdio/patologia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/patologia , Imageamento por Ressonância Magnética , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Colágeno , Fibrose , Espectroscopia de Ressonância Magnética , Meios de Contraste
19.
NMR Biomed ; 36(7): e4902, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36630472

RESUMO

MRI examinations are accurate for diagnosing sports-related acute hamstring injuries. However, sensitive imaging methods for assessing recovery of these injuries are lacking. Diffusion tensor imaging (DTI) and quantitative T2 (qT2) mapping have both shown promise for assessing recovery of muscle micro trauma and exercise effects. The purpose of this study was to explore the potential of DTI and qT2 mapping for monitoring the muscle recovery processes after acute hamstring injury. In this prospective study, athletes with an acute hamstring injury underwent a 3-T MRI examination of the injured and contralateral hamstrings including DTI and qT2 measurements at three time points: (1) within 1 week after sustaining the injury, (2) 2 weeks after time point 1, and (3) return to play (RTP). A linear mixed model was used for time-effect analysis and paired t-tests for the detection of differences between injured and uninjured muscles. Forty-one athletes (age 27.8 ± 7 years; two females and 39 males) were included. Mean RTP time was 50 (range 12-169) days. A significant time effect was found for mean diffusivity, radial diffusivity, and the second and third eigenvalues (p ≤ 0.001) in the injured muscles. Fractional anisotropy (p = 0.40), first eigenvalue (p = 0.02), and qT2 (p = 0.61) showed no significant time effect. All DTI indices, except for fractional anisotropy, were significantly elevated compared with control muscles right after the injury (p < 0.001). Values normalized during the recovery period, with no significant differences between control and injured muscles at RTP (p values ranged from 0.08 to 0.51). Mean qT2 relaxation times in injured muscles were not significantly elevated compared with control muscles at any time point (p > 0.04). In conclusion, DTI can be used to monitor recovery after an acute hamstring injury. Future work should explore the potential of DTI indices to predict RTP and recovery times in athletes after an acute strain injury.


Assuntos
Imagem de Tensor de Difusão , Músculos Isquiossurais , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Imagem de Tensor de Difusão/métodos , Estudos Prospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Músculos Isquiossurais/diagnóstico por imagem
20.
NMR Biomed ; 36(1): e4823, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36031706

RESUMO

High-risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self-gated, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe-/- atherosclerotic mice during natural disease progression. Twenty-four, 8-week-old, female Apoe-/- mice were divided into four groups (n = 6 each) and imaged with self-gated DCE-MRI at 4, 8, 12, and 16 weeks after high-fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high-fat diet and imaged longitudinally at the same time points. Aortic-root pseudo-concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash-in and washout slopes (b1 and b2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b2 , indicating contrast agent washout, was significantly higher in mice kept on an high-fat diet for longer periods of time (p = 0.03). Group comparison revealed significant differences between mice on a high-fat diet for 4 versus 16 weeks (p = 0.03). Macrophage density also significantly increased with diet duration (p = 0.009). Spearman correlation between b2 from DCE-MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE-MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single-slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.


Assuntos
Aorta Torácica , Meios de Contraste , Animais , Feminino , Camundongos , Progressão da Doença , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...